Page 16
background image

-

Check wiring between test box and 4-pin connector for open circuit using wiring diagram.

Contact 2 and socket 63
Wire resistance: Max. 1.5 Ohm

If no fault in wire is detected:

-

Replace engine control module.

Sensor and Sensor Control Check

NOTE:

-

Raise vehicle to reach oxygen sensor connector.

-

Only gold contacts may be used for servicing contacts 3 and 4 in connector for oxygen sensor.

Special tools and equipment

-

VAG1551 scan tool or VAG1552 mobile scan tool with VAG1551/3B cable

-

VAG1598/31 test box

-

VAG1526 hand multimeter or VAG1715 multimeter

-

VAG1594 adapter set

-

Wiring diagram

Check conditions

-

All fuses must be OK.

-

The battery voltage must be at least 11.5 V.

-

Exhaust system between catalyst and cylinder head must be free of leaks

-

Coolant temperature must be at least 80 °C, See display group 04, display zone 3.

Functional check

-

Connect VAG1551 scan tool (VAG1552). Start engine and select "Address word" 01 of engine control module. When doing this the engine must
be running at idling speed. (Connecting scan tool and selecting engine control module). Refer to "VAG1551 Scan Tool See: Computers and