Jetta L4-1588cc 1.6L DSL SOHC Turbo (1985)
Battery: All Technical Service Bulletins
Maintenance-Free Batteries - Recharging
Applies To All
Group
27
Subject Maintenance-free batteries
Part Identifier 2706
Key Points Recharging maintenance-free batteries in stock
(Supersedes Product Circular, Group 27, 84-01)
C
Number
85-02
August 8, 1985
Check voltage of maintenance-free batteries in stock with a digital voltmeter, on a routine basis every eight (8) weeks.
If battery voltage is below 12.4 V (75% charged), recharge battery to full capacity.
After charging battery and before measuring voltage, remove surface charge by applying a 15 amp load for
15 seconds.
To prevent storage related problems, batteries in stock longest should be sold first.