Customer Interest: > < Battery Charging - Minimum Charging Rates
Page 1
background image

Battery: All Technical Service Bulletins
Maintenance-Free Batteries - Recharging

Applies To All
Group

27
Subject Maintenance-free batteries

Part Identifier 2706
Key Points Recharging maintenance-free batteries in stock

(Supersedes Product Circular, Group 27, 84-01)

C

Number

85-02

August 8, 1985
Check voltage of maintenance-free batteries in stock with a digital voltmeter, on a routine basis every eight (8) weeks.

If battery voltage is below 12.4 V (75% charged), recharge battery to full capacity.

After charging battery and before measuring voltage, remove surface charge by applying a 15 amp load for

15 seconds.

To prevent storage related problems, batteries in stock longest should be sold first.