Jetta L4-1781cc 1.8L SOHC (ACC) Can (1995)
Fig. 5 - Inner Constant Velocity Joint, Installation Position Of Left-side Axle Shaft Boot
-
Mark shaft with tape at dimension -a- before installing boot.
-
Dimension -a- = 17 mm (0.67 in.)
NOTE: Do not scratch paint on shaft to mark dimension -a
Fig. 6 - Inner Constant Velocity Joint, Installation Position Of Right-side Axle Shaft Boot
-
Large diameter of vent chamber -A- must be on large tube diameter
-
B - Vent hole
Fig. 7 - Outer Constant Velocity Joint Boot, Ventilating
-
Before installing clamp on small diameter end of boot, lift boot slightly to equalize pressure and prevent vacuum inside causing an inward fold
-arrow- when driving.
Fig. 8 - Outer Constant Velocity Joint Clamps, Tensioning
CAUTION:
-
Clamp can only be tensioned using pliers tool No. V.A.G 1682 or Snap-On YA 3080, or equivalent.
-
Ensure that jaws of pliers contact the corners of the clamp arrow -B-.
-
Tension clamp by turning spindle to torque of 25 Nm (18 ft. lbs.)
NOTE: Coat the threads of the tool spindle with MoS2 grease to ensure smooth operation.