volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor Before Catalyst|Page 3852 > < Oxygen Sensor Before Catalyst|Page 3850
Page 15
background image

-

The oxygen sensor control after the Three Way Catalytic Converter (TWC) is superior to the oxygen sensor control before Three Way Catalytic
Converter (TWC) and is the regulation which makes corrections.

-

Slight changes in the mixture are corrected (e.g. enriching) via the oxygen sensor before the Three Way Catalytic Converter (TWC) by holding the
oxygen sensor control before Three Way Catalytic Converter (TWC) for a certain period (delay period) at the upper or the lower point. If the time
is in the positive range (e.g. 50 ms), the mixture will be enriched. If it is in the negative range (e.g. -50 ms), the mixture will be leaned.

-

If the delay period of the O2S control before the Three Way Catalytic Converter (TWC) increases to above 200 ms it is an indication that the
exhaust system is leaking.

If the specified values are obtained:

-

Press -> button.

-

Press buttons -0- and -6- to select "End Output" function 06 and press -Q- button to confirm input.

-

Turn off ignition.

Continuation

If B1-P2 OK appears in display field 4 and the value displayed in display field 3 is above 200 ms:

-

Check exhaust system for leaks.

If B1-P2 OK appears in display field 4 and the value displayed in display field 3 is above 1200 ms:

-

Press -> button.

-

Press buttons -0- and -6- to select "End Output" function 06 and press -Q- button to confirm input.

-

Perform test drive to remove possible residue on oxygen sensor and repeat check.

Observe the safety precautions when performing a road test. See: Fuel Delivery and Air Induction/Service Precautions/Technician Safety Information 

If the specified values are still not obtained:

-

Replace oxygen sensor behind Three Way Catalytic Converter (TWC) -G130-. Refer to item 34, See: Fuel Delivery and Air Induction/Locations 

-

Check DTC memory. If necessary, repair any malfunctions and erase DTC memory.
See: Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Reading Diagnostic Trouble Codes
See: Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Clearing Diagnostic Trouble Codes

 

-

Display readiness code.   See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes
If DTC memory has been erased or the Engine Control Module (ECM) was disconnected from permanent battery (B+) voltage, generate the
readiness code again.   See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

 
NOTE:  If the oxygen sensor voltage is OK and the delay period for the oxygen sensor control after the Three Way Catalytic Converter (TWC) is still
above 1200 ms even after a test drive, this points to an aged oxygen sensor before Three Way Catalytic Converter (TWC).

Evaluating display group 37, display field 2: Oxygen sensor voltage oxygen sensor after Three Way Catalytic Converter (TWC)

Oxygen Sensor Before Catalyst|Page 3852 > < Oxygen Sensor Before Catalyst|Page 3850