background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensor and Oxygen Sensor Control Behind Catalytic Converter, Checking

Oxygen Sensor And Oxygen Sensor Control Behind Catalytic Converter, Checking

NOTE:

-

Vehicle must be raised before connector for oxygen sensor is accessible.

-

When servicing terminals 3 and 4 in harness connector of Heated Oxygen Sensor (HO2S), use only gold-plated terminals.

Recommended special tools and equipment

-

V.A.G 1526 multimeter or V.A.G 1715 multimeter

-

V.A.G 1594 connector test kit

-

Wiring diagram

Requirements

-

The respective fuses of Heated Oxygen Sensor (HO2S) -G130- must be OK.

-

Battery voltage must be at least 11.5 Volts.

-

All electrical consumers such as, lights and rear window defroster must be switched off.

-

Parking brake must be engaged or else daylight driving lights will be switched on.

-

For vehicles with automatic transmission, selector lever must be in position -P- or -N-.

-

If vehicle is equipped with an A/C system, it must be switched off.

-

Ground (GND) connections between engine and chassis must be OK.

-

Exhaust system must be properly sealed between catalytic converter and cylinder head.

-

Coolant temperature must be at least 80 degrees C, Diagnostic mode 1: Check measured values; PID 5, Coolant temperature. See: Testing and
Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 1: Check Measured Values

-

Oxygen sensor heater for oxygen sensor behind catalytic converter must be OK, check. See: Oxygen Sensor Heater For Oxygen Sensor Behind
Three Way Catalytic Converter (TWC), Checking

Work sequence (Vehicles with engine code AEG, AVH, AZG, BEV)

-

Select output of oxygen sensor signals and check whether specified values are being reached, Diagnostic mode 5: Check output of oxygen sensor
signals. See: Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 5: Check Output of Oxygen
Sensor Signals

If specified values are obtained:

-

End diagnosis and switch ignition off.

If specified values are not obtained:

-

End diagnosis and let engine continue to run at idle.

-

Check primary voltage.

Checking primary voltage

Oxygen Sensor and Oxygen Sensor Control Before Catalytic Converter, Checking|Page 4087 > < Oxygen Sensor and Oxygen Sensor Control Before Catalytic Converter, Checking|Page 4085