Oxygen Sensor: Testing and Inspection
Oxygen Sensor Heater For Oxygen Sensor Before Three Way Catalytic Converter (TWC), Checking

Oxygen Sensor Heater For Oxygen Sensor Before Three Way Catalytic Converter (TWC), Checking

NOTE:

-

Vehicle must be raised before connector for oxygen sensor is accessible.

-

When servicing terminals in harness connector of oxygen sensor, use only gold-plated terminals.

Recommended special tools and equipment

-

V.A.G 1526 multimeter or V.A.G 1715 multimeter

-

V.A.G 1594 connector test kit

-

Wiring diagram

Requirements

-

The respective fuses of Heated Oxygen Sensor (HO2S) -G39- must be OK:

-

Ignition switched off.

Work sequence (Vehicles with engine code AEG)

-

Unscrew protective cover (arrows) and disconnect 4-pin harness connector (black) -1- to Heated Oxygen Sensor (HO2S) -G39- before catalytic
converter.

-

Check resistance for sensor heater at connector to oxygen sensor terminal 1 + 2.

Oxygen Sensor and Oxygen Sensor Control Before Catalytic Converter, Checking|Page 4091 > < Oxygen Sensor and Oxygen Sensor Control Before Catalytic Converter, Checking|Page 4089