volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Fuel Injector|Specifications|Page 4498 > < Fuel Injector|Specifications|Page 4496
Page 5
background image

Injection quantity and proper seal of fuel injectors, checking

Recommended special tools and equipment

-

V.A.G 1348/3A remote control with V.A.G 1348/3-2 adapter cable

-

V.A.G 1602 tester for quantity of injected fuel

Without illustration:

-

Without illustration:

Requirement

-

Fuel pressure must be OK, check fuel pressure regulator and retaining pressure. 

Work sequence

WARNING:  Fuel system is under pressure. Before opening system, place rags around the connection point. Then release pressure by carefully
loosening connection
.

-

Remove upper part of intake manifold.

Intake manifold, upper part, disassembling and assembling.

NOTE:  Seal the intake channels in lower section of intake manifold using a clean rag.

-

Disconnect fuel injector connectors.

-

Remove and support fuel rail with fuel injectors:

Intake manifold, lower part, disassembling and assembling:

-

Connect test box to control module wiring harness, connect test box for wiring test. See: Computers and Control Systems/Testing and
Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/Test Box, Connecting For Wiring Test

Vehicles with engine code AEG

-

Bridge sockets 2 + 4 of test box with the respective adapter cables. Fuel Pump (FP) must run.

Fuel Injector|Specifications|Page 4498 > < Fuel Injector|Specifications|Page 4496