Continued for all vehicles

-

Connect multimeter to terminal 1 (B+) and 3 (Ground) of connector for Camshaft Position (CMP) sensor for voltage measurement.

-

Switch ignition on.

Specified value: 4.0 to 6.0 V

-

Switch ignition off.

If there is no voltage:

-

Connect test box to control module wiring harness, connect test box for wiring test. See: Computers and Control Systems/Testing and
Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/Test Box, Connecting For Wiring Test

-

Check wires between test box and connector for open circuit according to wiring diagram.

Terminal 1 + socket 98
Terminal 2 + socket 86
Terminal 3 + socket 108

Wire resistance: max. 1.5 Ohms

-

Check wires for short circuit to each other.

-

Specified value: Infinite Ohms

If no malfunctions are found in the wires and there was voltage between terminals 1 + 3:

-

Replace Camshaft Position (CMP) sensor -G40-

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data. See: Computers and Control
Systems/Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data

-

Generate readiness code. See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes.

If no errors are found in wires and there was no voltage between terminals 1 + 3:

-

Replace Motronic Engine Control Module (ECM) -J220-.