Jetta V6-2.8L (AFP) (1999)
Service Port HVAC: Service and Repair
Low pressure service valve, removing
-
Discharge refrigerant system before replacing valve -3-. Only use Kent Moore ACR4 or equivalent.
NOTE: Protect all opened components against contamination of did and moisture with suitable plastic caps.
1
-
Base with outside thread and groove for -O-ring
2
-
O-ring
-
Always replace
-
7,6 mm; 1,8 mm
3
-
Service valve
4
-
O-ring
-
Always replace
-
7,6 mm; 1,8 mm
5
-
Cap
High pressure service valve, removing
-
Discharge refrigerant system before replacing valve -3-. Only use Kent Moore ACR4 or equivalent.
NOTE: Protect all opened components against contamination of dirt and moisture with suitable plastic caps.
1
-
Base with inside thread
2
-
O-ring
-
Always replace
-
10,8 mm; 1,8 mm
3
-
Service valve with groove and inside thread for cap.
4
-
O-ring
-
Always replace