Jetta V6-2.8L (AFP) (1999)
Leak Detection Pump: Testing and Inspection
With Generic Scan Tool
Check Leak Detection Pump (LDP)
Recommended special tools and equipment
-
VAG1526 multimeter or VAG1715 multimeter
-
VAG1594 connector test kit
-
Wiring diagram
Test requirements
-
The respective fuses of Leak detection pump (LDP) -V144- must be OK.
-
Ignition switched off.
Test sequence
-
Remove rear right wheelhousing liner.
-
Disconnect 3-pin connector of Leak detection pump (LDP) -V144-(arrow).
-
Measure resistance between terminals 1 + 3 of diagnostic pump.
Specified value: 640...720 Ohms
-
Measure resistance between terminals 2 + 3 of diagnostic pump.
Specified value: 12.5...19.5 Ohms