volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 3076 > < Oxygen Sensor and O2 Sensor Control After TWC, Checking
Page 2
background image

"Scan Tool Testing/Scan Tool Connecting and Initial Checks".  

See: Testing and Inspection

Indicated on display:

Rapid data transfer 

HELP

Select function XX

-

Press buttons -0- and -8- for function "Read measured value (data) block" and confirm entry with -Q- button.

Indicated on display:

Read measured value block
Input display group number XXX

-

Press buttons -0-, -3- and -0- for "Display group number 30" and confirm entry with -Q- button.

Indicated on display: (1 to 2 = display zones)

Read measured value block 30 

->

2

-

Check Oxygen Sensor control status after Three Way Catalytic Converter (TWC) (display zone 2).
Specification: 111
Significance of figures in 3 digit number block.  Refer to "Measuring Value Blocks/Measuring Value Blocks/Evaluating Measured Value Blocks".
 

See: Testing and Inspection

NOTE:  The bits in display zone 1 will not be set to 1 until the Three Way Catalytic Converter (TWC) temperature rises above 380 degrees C (See
display groups 34, display zone 2) and a part load signal is recognized by the Motronic Engine Control Module (ECM) -J220-.

If the specification is not obtained:

-

Press the -> button.

-

Check Oxygen Sensor (O2S) heating after Three Way Catalytic Converter (TWC).  

See: 

If the specification is obtained:

-

Change to display group 36 as follows:

-

Press -C- button.

Indicated on display:

Read measured value block
Input display group number XXX

-

Press buttons -0-, -3- and -6- for "Display group number 36" and confirm entry with -Q- button.

Indicated on display: (1 to 4 = display zones)

Read measured value block 36 

->

4

-

Check Oxygen Sensor (O2S) voltage after Three Way Catalytic Converter (TWC) in display zone 1:
Specification: 0.100 to 0.900 V (must fluctuate slightly)

If the display in display zone 1 fluctuates:

-

Press the -> button.

-

Press buttons -0- and -6- for function "End output" and confirm entry with the -Q- button.

-

Switch off ignition.

If the display in display zone 1 remains constantly at a value:

-

Press the -> button.

-

Press buttons -0- and -6- for function "End output" and confirm entry with the -Q- button.

-

Switch off ignition.

-

Check basic voltage of Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) -G130-.  

See: 

Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 3076 > < Oxygen Sensor and O2 Sensor Control After TWC, Checking