volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 3091 > < Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 3089
Page 5
background image

-

VAG 1551 Scan tool (or VAG 1552) with VAG 1551/3 adapter cable

NOTE:  All functions which could previously be performed with VAG 1551/1552 can also be performed with the VAS 5051.

-

VAG 1526 Hand multimeter or VAG 1715 multimeter

-

VAG 1594 Adapter set

-

VAG 1598/31 Test box

-

Electrical Wiring Diagrams

Test prerequisites

-

The fuses must be OK.

-

The battery voltage must be at least 11.5 V.

-

All electrical accessories, e.g. lights and rear window heating must be switched off.

-

If the vehicle is equipped with air conditioning, it must be switched off.

-

Selector lever must be in position "P" or "N" on vehicles with an automatic transmission.

-

Fuel Pump (FP) relay -J17- must be OK., checking:

Test Sequence

-

Connect VAG 1551 Scan tool (or VAG 1552) and select engine electronics control module with the "Address word" 01. When doing this the
engine must be running at idle speed: ((VAG 1551 and Motronic Engine Control Module (ECM) -J220-, connecting and selecting).  

See: Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/With Manufacturer's Scan Tool/Connecting VAG
1551 Scan Tool

Indicated on display:

Rapid data transfer 

HELP

Select function XX

-

Press buttons -0- and -8- for function "Read measured value (data) block" and confirm entry with -Q- button.

Indicated on display:

Read measured value block
Input display group number XXX

-

Press buttons -0-, -4- and -1- for "Display group number 41" and confirm entry with -Q- button.

Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 3091 > < Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 3089