background image

-

Commercially available hydrometer

WARNING!

-

Refer to Warnings and Safety Measures.

-

If electrolyte level is too high, electrolyte (sulfuric acid/water mixture) may leak out and damage the surrounding area, i.e.: plenum and
engine compartment

-

Excess electrolyte MUST be extracted using a hydrometer

-

Dispose of electrolyte (sulfuric acid) properly! Waste electrolyte must only be disposed of in appropriate waste disposal sites. Refer to
local regulations pertaining to electrolyte disposal

-

Remove cell caps from cells with excess electrolyte.

-

Extract excess electrolyte using hydrometer until electrolyte level is lowered to internal level indicator -1- or external maximum marking.

CAUTION!
Use use of genuine VW battery cell caps ensures the different battery cover systems are sealed correctly. Only use genuine cell caps of the same
construction if lost or damaged. All cell caps must be equipped with an O-ring seal.