volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor (O2S) Aging Oxygen Sensor 1, Checking|Page 3363 > < Oxygen Sensor (O2S) Aging Oxygen Sensor 1, Checking|Page 3361
Page 5
background image

Specification: 1 1 1

Significance of 3 digit number block in display zone 1:

If the specification is not obtained:

-

Check heated oxygen sensor before catalyst. See: Checking

If the specification is obtained:

-

Change to display group 32 as follows:

-

Press C key.

-

Press keys 0, 3 and 2 for "Display group number 32" and confirm entry with Q key.

Indicated on display: (1-4 = Display zones)

Read measured value block 32

->

1

2

3

4

-

Check Oxygen sensor control learned values at idling speed (additive) in display zone 1.
Specification: -10.0 - 10.0 %

-

Check Oxygen sensor control learned values at part load (multiplicative) in display zone 2.
Specification: -10.0 - 10.0 %

If the specification is not obtained:
Evaluating display group 32. Refer to "Scan Tool Testing/Measuring Value Blocks/Display Groups 30-49, 99, 107 (Oxygen Sensor Control)" See:
Testing and Inspection 

If the specification is obtained:

-

Change to display group 33 as follows:
VAG 1551: Press key 3
VAG 1552: Press key up arrow

Indicated on display: (1-4 = Display zones)

Read measured value block 33

-> 

4

-

Observe Oxygen sensor control in display zone 1.
-

The display must fluctuate at least 2% in the range -10.0 - 10.0 %

-

Check Oxygen sensor voltage in display zone 2.
-

The voltage must fluctuate at least 20 times per minute in range of 0 - 1.0 V.

Oxygen Sensor (O2S) Aging Oxygen Sensor 1, Checking|Page 3363 > < Oxygen Sensor (O2S) Aging Oxygen Sensor 1, Checking|Page 3361