volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3446 > < Initial Inspection and Diagnostic Overview|Page 3444
Page 5
background image

-

Generate readiness code. See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

If resistance value is in specified range:

-

Re-connect connectors to control module for Diesel-Direct fuel injection system.

-

Remove air filter housing.

-

Disengage connector from ABS control module and disconnect.

-

Check CAN-Bus wires with terminal resistance in control module for Diesel-Direct fuel injection system.

-

To do so, measure resistance anew between test box sockets 3 +25:
Specified value: 115...135 Ohm

If resistance value is not in specified range:

-

Check CAN-Bus wires.

If no malfunctions are detected in wires:

-

Replace Diesel Direct Fuel Injection (DFI) Engine Control Module (ECM) -J248-

-

Generate readiness code. See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

Checking CAN-Bus wires

-

Remove air filter housing.

-

Disengage connector from ABS control module and disconnect.

-

Disengage connectors from control module for Diesel-Direct fuel injection system and disconnect the connectors.

-

Check CAN data bus wires for short circuit to each other.

-

To do so, measure resistance anew between test box sockets 3 + 25 at V.A.G 1598/18 Adapter - 68-pin:
Specified value: Infinite Ohm

If specified value is not obtained (wires have shorts):

-

Eliminate error in wires according to wiring diagram.

-

Erase DTC memory of control module for Diesel-Direct fuel injection system, Diagnostic mode 4: Reset/erase diagnostic data. See: Testing and
Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode, Selecting/Diagnostic Mode 4: Reset/Erase Diagnostic
Data

-

Generate readiness code. See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

If specified value is obtained (wires have no short circuit to each other):

-

Connect test box to control module wiring harness, connect test box for wiring test. See: Testing and Inspection/Reading and Clearing Diagnostic
Trouble Codes/Scan Tool Connecting/With Generic Scan Tool/Test Box, Connecting For Wiring Test

-

Check CAN-Bus wires between test box sockets for open circuit according to wiring diagram:
Socket 68 (1598/22) and Socket 3 (1598/18)

Initial Inspection and Diagnostic Overview|Page 3446 > < Initial Inspection and Diagnostic Overview|Page 3444