volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 5985 > < Symptom Related Diagnostic Procedures|Page 5983
Page 9
background image

Design of filler support on filling bottle VAS 5045 prevents overfilling of battery cells and subsequent electrolyte leaks. When max. level is reached the
flow of distilled water into battery cells stops.

CAUTION!

-

Only use distilled water to top-up batteries. This prevents electrolyte impurities which cause self-discharging.

-

DO NOT overfill the battery

-

Overfilled batteries can boil over.

-

Too little electrolyte reduces the service life of the battery.

-

Use use of genuine VW battery cell caps ensures the different battery cover systems are sealed correctly. Only use genuine cell caps of the
same construction if lost or damaged. All cell caps must be equipped with an O-ring seal

Electrolyte level too high

Special tools, testers and auxiliary items needed

-

Commercially available hydrometer

WARNING!

-

Refer to Warnings and Safety Measures.

-

If electrolyte level is too high, electrolyte (sulfuric acid/water mixture) may leak out and damage the surrounding area, i.e.: plenum and
engine compartment.

Symptom Related Diagnostic Procedures|Page 5985 > < Symptom Related Diagnostic Procedures|Page 5983