Unscrew protective cover (arrows) and disconnect 6-pin harness connector (black) -1- to Heated Oxygen Sensor (HO2S) -G39- before catalytic
converter.

-

Check resistance for sensor heater at connector to oxygen sensor terminal 3 + 4. Specified value: 2,5 ... 10,0 Ohms (at room temperature)

If specified value is not obtained:

-

Replace Heated Oxygen Sensor (HO2S) 1 Bank 1 -G39- before catalytic converter, item 5.

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data. See: Testing and Inspection/Scan Tool
Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data 

-

Generate readiness code.   See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes 

If specified value is obtained:

-

Check Ground (GND) activation of oxygen sensor heater.

-

Connect test box to control module wiring harness, connect test box for wiring test. See: Testing and Inspection/Reading and Clearing Diagnostic
Trouble Codes/Scan Tool Connecting/With Generic Scan Tool/Test Box, Connecting For Wiring Test 

-

Check wires between test box and 6-pin connector to Engine Control Module (ECM) for open circuit according to wiring diagram.
Terminal 4 + socket 5
Wire resistance: max: 1.5 Ohms

-

Also check wires for short circuit to B+ and Ground (GND). Specified value: Infinite Ohms

-

Check wire between 6-pin connector terminal 3 and the Fuel Pump (FP) Relay -J17- for open circuit according to wiring diagram. Wire resistance:
max: 1.5 Ohms

If no malfunctions are found in wires:

-

Replace Motronic Engine Control Module (ECM) -J220-.

With Manufacturer's Scan Tool

Oxygen Sensor Heater For Heated Oxygen Sensor (H02S) -G39-, Checking

NOTE:

-

Vehicle must be raised before connector for oxygen sensor is accessible.

-

When servicing terminals in harness connector of Heated Oxygen Sensor (HO2S), use only gold-plated terminals.

Special tools and equipment

-

V.A.G1551 scan tool (or VAG1552 mobile scan tool) with VAG1551/3 cable

-

VAG1598/31 test box