volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor Before Catalyst|Page 3621 > < Oxygen Sensor Before Catalyst|Page 3619
Page 10
background image

-

Connect multimeter for voltage measurement to terminals 3 + 4 of connector to Engine Control Module (ECM) and measure primary voltage.
Specified value: 0.400 to 0.500 Volts

-

Switch ignition off.

If specified value is not obtained:

-

Test oxygen sensor wires.

If specified value is obtained:

-

Replace Oxygen Sensor (O2S) 2 Bank 1 Behind Three Way Catalytic Converter (TWC) -G130-:
-

Vehicles with engine code AEG, item 10,

-

Vehicles with engine code AVH, AZG, item 13.

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data. See: Testing and Inspection/Scan Tool
Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data 

-

Generate readiness code.   See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes 

Checking oxygen sensor wires

-

Connect test box to control module wiring harness, connect test box for wiring test. See: Testing and Inspection/Reading and Clearing Diagnostic
Trouble Codes/Scan Tool Connecting/With Generic Scan Tool/Test Box, Connecting For Wiring Test 

Vehicles with engine code AEG

-

Check wires between test box and 4-pin connector (to control module) for open circuit according to wiring diagram.
Terminal 3 + socket 51
Terminal 4 + socket 52
Wire resistance: max: 1.5 Ohms

Vehicles with engine code AVH, AZG

Oxygen Sensor Before Catalyst|Page 3621 > < Oxygen Sensor Before Catalyst|Page 3619