volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

With Generic Scan Tool|Page 3778 > < Leak Detection Pump, Evaporative System|Locations|Page 3775
Page 1
background image

Leak Detection Pump: Testing and Inspection
With Generic Scan Tool

Check Leak Detection Pump (LDP)

Recommended special tools and equipment

-

VAG1526 multimeter or VAG1715 multimeter

-

VAG1594 connector test kit

-

Wiring diagram

Test requirements

-

The respective fuses of Leak detection pump (LDP) -V144- must be OK.

-

Ignition switched off.

Test sequence

-

Remove rear right wheelhouse liner.

-

Disconnect 3-pin connector of Leak detection pump (LDP) -V144- (arrow). 

-

Measure resistance between terminals 1 + 3 of diagnostic pump. Specified value: 640 ... 720 Ohms

-

Measure resistance between terminals 2 + 3 of diagnostic pump. Specified value: 12,5 ... 19,5 Ohms

If specified values are not obtained:

-

Replace Leak Detection Pump (LDP) -V144-, item 8