volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Air Flap Motors (For Climate Control Regulation), Replacing|Page 6484 > < Air Door Actuator / Motor, HVAC|Locations
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Air Flap Motors (For Climate Control Regulation), Replacing

Air Flap Motors (for Climate Control Regulation), Replacing

CAUTION!
Before beginning repairs on the electrical system:

-

Obtain the anti-theft radio security code.

-

Switch the ignition off.

-

Disconnect the battery Ground (GND) strap.

-

After reconnecting battery, re-code and check operation of anti-theft radio. Also check operation of clock and power windows.

NOTE:  After installing flap motors:

-

Ensure wiring is correctly routed. Harnesses must be routed so that they do not come into contact with moving parts (for example the levers on the
flap motors).

-

Initiate Basic setting, function 04 See Climatronic OBD.

Air flow flap motor -V71-, removing and installing

NOTE:  The air flow flap motor also operates the fresh/recirculating air flap.

Removing

-

Remove glove box.

-

With screwdriver, carefully unclip air flow flap rod -1- from lever -2-.

-

Disconnect electrical connector -1-.

-

Remove screw -3-.

The flap motor is connects to the evaporator housing portion of the heating and A/C unit. To prevent damage:

-

Lower flap motor and at the same time pull off fresh air/recirculating air flap shaft -2-, arrow -A-.

Air Flap Motors (For Climate Control Regulation), Replacing|Page 6484 > < Air Door Actuator / Motor, HVAC|Locations