volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Condenser HVAC > < High Pressure Service Valve
Page 1
background image

Compressor Fitting HVAC: Service and Repair
Low Pressure Service Valve

NOTE:  Before carrying out any work on the A/C refrigerant system, refer to A/C refrigerant system safety measures. See: Service Precautions 

Low Pressure Service Valve, Removing

-

Discharge refrigerant system before replacing valve -3-. Only use Kent Moore ACR4 or equivalent.

NOTE:  Protect all opened components against contamination of dirt and moisture with suitable plastic caps.

1

-

Base with outside thread and groove for -O-ring

2

-

O-ring
Always replace 
7.6 mm; 1.8 mm

3

-

Service valve

4

-

O-ring
Always replace 
7.6 mm; 1.8 mm

5

-

Cap

Condenser HVAC > < High Pressure Service Valve