Oxygen Sensor: Testing and Inspection
Oxygen Sensor and O2 Sensor Control After TWC, Checking

Sensor and Control Check

Oxygen Sensor and Oxygen Sensor Control (After Three Way Catalytic Converter (TWC)), Checking

NOTE:  Only gold plated contacts must be used to repair terminals 3 and 4 in the oxygen sensor harness connectors.

Special tools and equipment

-

VAG1551 Scan Tool (ST) or VAG1552 mobile scan tool with VAG1551/3 adapter cable

-

VAG1598/31 test box

-

Multimeter (Fluke 83 or equivalent)

-

VW1594 adapter set

-

Wiring diagram

Test requirements

-

Fuse 43 OK

-

Exhaust system between Three Way Catalytic Converter (TWC) and cylinder head free of leaks

-

Coolant temperature at least 85 °C = display group 04, display field 3

Functional check

-

Press buttons -0- and -1- to insert "Engine Electronics" address word 01. When doing this engine must be running at idle (connecting scan tool and
selecting engine electronics control module.   

Indicated on display

Rapid data transfer 

HELP

Select function XX

-

Press buttons -0- and -4- to select "Basic Setting" function 04 and press -Q- button to confirm input.

Indicated on display

Basic Setting
Input display group number XXX

-

Press buttons -0-, -3-, and -0- to input display group number 30 (030) and press - Q- button to confirm input.

Indicated on display: (1-2 = display fields)

Read Measuring Value Block 30

->

1

2

-

Check status of oxygen sensor control after Three Way Catalytic Converter (TWC) (display field 2).

Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 3560 > < Bank 1, Sensor 1 Oxygen Sensor|Page 3557