volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 1205 > < Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 1203
Page 6
background image

-

The O2S sensor has been damaged by leaded fuel

Checking basic voltage for oxygen sensor 2

-

Remove protective cover (arrows) and disconnect 4-pin harness connector (brown) -1 - to oxygen sensor after Three Way Catalytic Converter
(TWC) -G130-.

-

Connect multimeter using auxiliary cables from VW1594 to measure voltage at terminals 3 + 4 (harness connector to Motronic Engine Control
Module (ECM)).

-

Start engine and measure basic voltage.
Specified value: 0.400-0.500 V

-

Switch ignition off.

If the specified value is not obtained:

-

Check oxygen sensor wiring.

If the specified value is obtained:

-

Replace oxygen sensor behind Three Way Catalytic Converter (TWC) -G130-. Refer to item 28 under "Fuel Delivery and Air Induction/Fuel
Injector", See: Powertrain Management/Fuel Delivery and Air Induction/Service and Repair 

-

Check DTC memory. If necessary, repair any malfunctions and erase DTC memory.   

-

Display readiness code.    

If DTC memory has been erased or the Engine Control Module (ECM) was disconnected from permanent battery (B+) voltage, the readiness code
must be generated again.   

Checking oxygen sensor wiring, oxygen sensor 2

-

Remove wiper arms and plenum chamber cover.

Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 1205 > < Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 1203