volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 1232 > < Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 1230
Page 2
background image

-

Check resistance for sensor heater at connector to oxygen sensor terminal 1 + 2.
Specified value: 6,4...47,5 Ohm (at room temperature)

If specified value is not obtained:

-

Replace Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) -G130-:
-

Vehicles with engine code AFP, item 9.

-

Vehicles with engine code BDF, item 13.

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data. 

See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan
Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data

-

Generate readiness code. 

See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

If specified value is obtained:

-

Check Ground (GND) activation of oxygen sensor heater.

-

Connect test box to control module wiring harness, connect test box for wiring test. 

See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool
Connecting/With Generic Scan Tool/Test Box, Connecting For Wiring Test

-

Check wires between test box and 4-pin connector to Engine Control Module (ECM) for open circuit according to wiring diagram.
Terminal 2 + socket 63
Wire resistance: max: 1.5 Ohm

-

Also check wires for short circuit to B+ and Ground (GND).
Specified value: infinite Ohm

-

Check wire between 4-pin connector terminal 1 and Fuel Pump (FP) Relay -J17- for open circuit according to wiring diagram.
Wire resistance: max: 1.5 Ohm

If no malfunctions are found in wires:

-

Replace Motronic Engine Control Module (ECM) -J220-.

Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 1232 > < Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 1230