volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Battery Handling Instructions|Page 5825 > < Battery Handling Instructions|Page 5823
Page 4
background image

Battery is inserted correctly when center cut-out in battery foot strip aligns with threaded hole in battery carrier -arrows-

-

On batteries with a hose for central venting ensure that the hose is not squashed. Only then can the battery vent freely.

-

On batteries without a hose for central venting ensure that the opening on the upper side of the battery cover is not blocked.

NOTE:  New generation batteries are equipped with a central gas venting system and The grated flame trap. Function: Gases produced during charging
escape through a central opening on the side of the upper cover. The integrated flame trap prevents flammable gases in the battery from igniting. The
flame trap is comprised of a small round fiberglass mat with a diameter of 15 mm and a thickness of 2 mm. Working as a one-way-valve, it allows gases
produced during charging to vent.

-

Fit battery hold-down bracket and tighten M8 x 30 securing bolt to 22 Nm.

-

Install positive clamp onto battery positive terminal.

NOTE:

-

Battery terminal clamps must only be fitted by hand without force, this prevents damage to battery housing.

-

Battery terminals must no longer be greased.

-

Tighten battery positive terminal clamp securing screw to 6 Nm.

-

Release elastic cord from fuse holder and slide into mounting.

Battery Handling Instructions|Page 5825 > < Battery Handling Instructions|Page 5823