Technical Service Bulletin # 8708-01
Date: 080118
A/C - Blower Motor Operates On High Only
87 08 01
January 18, 2008
2017121
Affected Vehicles
Condition
HVAC Blower Fan Speed Can Not Be Regulated
HVAC blower operates only on high speed setting. Fan speed setting cannot be regulated.
Note:
The condition as described does not compromise visibility.
Technical Background
Heavy snow and ice accumulated through the cabin air intake cowl may cause the HVAC blower to become obstructed and cause the blower speed to
operate only on high speed (unregulated) setting.
Production Solution
No production change required.
Service