See diagram for specified value
Range A displays resistance values for the temperature range of 0 to 65 degrees C, range B displays resistance values for the temperature range of 65 to
100 degrees C
.

Read-out examples:

-

30 degrees C corresponds to a resistance of 3790 to 4270 Ohms

-

80 degrees C corresponds to a resistance of 600 to 660 Ohms

If specified value is not obtained:

-

Replace Fuel Temperature Sensor -G81-.

-

Erase DTC memory of control module for Diesel-Direct fuel injection system, Diagnostic mode 4: Reset/erase diagnostic data. See: Computers
and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase
Diagnostic Data

-

Generate readiness code. See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

If specified value is obtained:

-

Check wires to control module according to wiring diagram.

Check wires to control module

-

Connect test box to control module wiring harness, connect test box for wiring test. See: Computers and Control Systems/Testing and
Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/Test Box, Connecting For Wiring Test

Vehicles with 80-pin control module

-

Check for open circuits in wires between test box and connector according to wiring diagram.

Terminal 4 + socket 76
Terminal 7 + socket 53

Wire resistance: max. 1.5 Ohms