volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 2838 > < Overview of Component Locations|Page 2835
Page 1
background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensor and O2 Sensor Control After TWC, Checking

Sensor and Control Check

Oxygen Sensor (O2S) and Oxygen Sensor Control After Three Way Catalytic Converter (TWC), Checking

NOTE:

-

The vehicle must be raised to gain access to the Oxygen Sensor (O2S) connector.

-

Only gold plated terminals may be used to service the terminals in the Oxygen Sensor (O2S) connectors.

Special tools, workshop equipment, testers, measuring instruments and auxiliary items required

-

VAG 1551 Scan tool (or VAG 1552) with VAG 1551/3 adapter cable

NOTE:  All functions which could previously be performed with VAG 1551/1552 can also be performed with the VAS 5051.

-

VAG 1526 Hand multimeter or VAG 1715 multimeter

-

VAG 1594 Adapter set

-

VAG 1598/31 test box

-

Electrical Wiring Diagrams

Test prerequisites

-

The fuses must be OK.

-

The battery voltage must be at least 11.5 V.

-

All electrical accessories, e.g. lights and rear window heating must be switched off.

-

If the vehicle is equipped with air conditioning, this must be switched off.

-

Selector lever must be in position "P" or "N" on vehicles with an automatic transmission.

-

Exhaust system between Three Way Catalytic Converter (TWC) and cylinder head must be free of leaks.

-

Engine Coolant Temperature (ECT) must be at least 85 degrees C, See display group 1, display zone 2.

-

Three Way Catalytic Converter (TWC) temperature must be at least 380 degrees C, See display group 34, display zone 2.

Functional check

-

Connect VAG 1551 Scan tool (or VAG 1552) and select engine electronics control module with the "Address word" 01. When doing this the
engine must be running at idle speed: ((VAG 1551 and Motronic Engine Control Module (ECM) -J220-, connecting and selecting).  Refer to

Oxygen Sensor and O2 Sensor Control After TWC, Checking|Page 2838 > < Overview of Component Locations|Page 2835