Jetta Sedan V6-2.8L (BDF) (2003)
-
Connect hand vacuum pump ((V.A.G 1390) to vacuum connection of combination valve (arrow).
-
Disconnect pressure hose to combination valve at coupling (arrow) and blow into it with light pressure.
Combination valve must close.
NOTE: To disengage, compress the buttons at the hose coupling.
-
Operate vacuum pump.
Combination valve must open.
If the combination valve does not open or it is constantly open:
-
Replace combination valve.