volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Canister Purge Control Valve|Testing and Inspection|Page 2398 > < Canister Purge Control Valve|Testing and Inspection
Page 2
background image

Checking internal resistance 

-

Using a multimeter, check the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) terminals 1 and 2 for resistance.

Specified value: 15.0 to 25.0 ohms.

If the specified value was Not obtained:

-

Replace the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80). 

If the specification is obtained:

Checking voltage supply

-

Using a multimeter, check the purge valve electrical harness connector terminal 1 to 2 for voltage.

-

Turn ignition switch ON.

Specified value: 10.6 volts ± 2 volts.

If the specified value was Not obtained:

-

Leave the multimeter positive lead on terminal 1 and connect the multimeter negative lead to engine ground.

-

Ignition switch ON.

Specified value: battery voltage.

If the specified value was Not obtained:

Canister Purge Control Valve|Testing and Inspection|Page 2398 > < Canister Purge Control Valve|Testing and Inspection