Open the shut off valve on the (VAG 1318). The lever points in the direction of flow.

-

Bleed the fuel system. Refer to --> [ Fuel System, Bleeding ] See: Service and Repair/Procedures. 

-

Start the engine and run at idle speed.

-

Measure the fuel pressure.

Specified value: approximately 4.0 bar positive pressure

If the Specification is Not Obtained:

-

Switch off the ignition.

-

Check the delivery quantity of the fuel pump. Refer to --> [ Delivery Quantity, Checking ] See: Testing and Inspection/Fuel Pump, Checking.

-

If the fuel pump is OK, replace the fuel filter/pressure regulator. 

‹› From October 2005, the fuel pressure regulator is integrated in the fuel filter and cannot be replaced.

If the Specified Value is Achieved:

-

Switch off the ignition.

-

Now check for leaks and residual pressure (entire system). Observe the pressure drop on the (VAG 1318).

After 10 minutes there must be a residual pressure of at least 3.0 bar.

If the holding pressure drops below 3 bar:

-

Start the engine and run at idle speed.

-

Wait until pressure has built up, then switch off the ignition. Simultaneously close the shut off valve on the (VAG 1318) (lever perpendicular to
direction of flow) - arrow -.