volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor O2S 1 Before Catalytic Converter Heater, Checking|Page 1785 > < Oxygen Sensor O2S 1 Before Catalytic Converter Heater, Checking|Page 1783
Page 2
background image

-

Select "Monitor-ID $01: Oxygen sensor monitoring before catalytic converter".

-

Select "Test-ID $83: Dynamic test".

-

Check the specified values at idle.

If specified values are obtained:

-

End diagnosis and switch the ignition off.

If the specified values are not obtained:

Checking primary voltage

-

Disconnect the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector - 1 -.

-

Using a multimeter, connect the negative lead to engine ground. Check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector
terminals 1,2,5, and 6 for voltage.

Specified value: 2.40 V - 2.99 V

-

Switch the ignition off.

Oxygen Sensor O2S 1 Before Catalytic Converter Heater, Checking|Page 1785 > < Oxygen Sensor O2S 1 Before Catalytic Converter Heater, Checking|Page 1783