Depending on battery type, the charger switches over to sustain charging after approximately 1-7 hours. To achieve a 100% charge status, the
battery should remain connected to the charger for that long.

Possible malfunctions and how they are handled:

1 Displayed voltage does not match the nominal voltage: Hold the appropriate button Up (UP arrow) or Down (Down arrow), until the charging process
begins. Displayed battery voltage does not match the nominal voltage - the charging process has already begun: Press START / STOP twice. Hold the
appropriate button Up (UP arrow) or Down (Down arrow) until the charging process begins again. The charger does not recognize a battery, when the
battery voltage is less than 2 V: The display remains unchanged. The selected battery type and Ampere hours (Ah) are displayed.

End battery charging process:

-

Press START / STOP.

-

Remove the black charging clamp "-" of the charger from the negative battery terminal.

-

Remove the red charging clamp "+" of the charger from the positive battery terminal.

-

Pull out the electrical system connector of the charger.

Service Charge

Service Charge

CAUTION:

-

Risk of injury. Observe warning notes and safety precautions.

-

Batteries that have a colorless or light yellow visual indicator must not be tested or charged. Jump starting must not be used.

-

There is a risk of explosion during testing, charging or jump starting.

-

These batteries must be replaced.

-

"Service charging" is not permitted for VW vehicles, because voltage surges can damage the on-board electronics.

-

If "Service charging" is still used, the battery must always be separated from the vehicle electrical system.

-

During the charging process, always set the operation mode corresponding with the battery operation instructions for battery charger
VAS 5900

-

"Service Charging" is suitable for:
-

wet batteries on which the visual indicator permits charging (indicator black or green).

"Service Charging (SERV)" is only used on sulfated batteries. Batteries with voltage > 14.4 V are charged. A partial removal of the sulfation layer can
result from this. Check the visual indicator immediately after charging, before the battery is used.

Special tools, testers and auxiliary items required

-

Battery Charger VAS 5903 VAS 5900

NOTE:  The battery temperature must be at least 10 degrees C.

-

Turn off the ignition and all electrical consumers.

-

Plug in the electrical system connector of the charger. The last selected operation mode is shown on the display.