Jetta SportWagen L5-2.5L (CBUA) (2009)
-
Depending on battery type, the charger switches over to sustain charging after approximately 1-7 hours. To achieve a 100% charge status, the
battery should remain connected to the charger for that long.
Possible malfunctions and how they are handled:
1 Displayed voltage does not match the nominal voltage: Hold the appropriate button Up (UP arrow) or Down (Down arrow), until the charging process
begins. Displayed battery voltage does not match the nominal voltage - the charging process has already begun: Press START / STOP twice. Hold the
appropriate button Up (UP arrow) or Down (Down arrow) until the charging process begins again. The charger does not recognize a battery, when the
battery voltage is less than 2 V: The display remains unchanged. The selected battery type and Ampere hours (Ah) are displayed.
End battery charging process:
-
Press START / STOP.
-
Remove the black charging clamp "-" of the charger from the negative battery terminal.
-
Remove the red charging clamp "+" of the charger from the positive battery terminal.
-
Pull out the electrical system connector of the charger.
Service Charge
Service Charge
CAUTION:
-
Risk of injury. Observe warning notes and safety precautions.
-
Batteries that have a colorless or light yellow visual indicator must not be tested or charged. Jump starting must not be used.
-
There is a risk of explosion during testing, charging or jump starting.
-
These batteries must be replaced.
-
"Service charging" is not permitted for VW vehicles, because voltage surges can damage the on-board electronics.
-
If "Service charging" is still used, the battery must always be separated from the vehicle electrical system.
-
During the charging process, always set the operation mode corresponding with the battery operation instructions for battery charger
VAS 5900
-
"Service Charging" is suitable for:
-
wet batteries on which the visual indicator permits charging (indicator black or green).
"Service Charging (SERV)" is only used on sulfated batteries. Batteries with voltage > 14.4 V are charged. A partial removal of the sulfation layer can
result from this. Check the visual indicator immediately after charging, before the battery is used.
Special tools, testers and auxiliary items required
-
Battery Charger VAS 5903 VAS 5900
NOTE: The battery temperature must be at least 10 degrees C.
-
Turn off the ignition and all electrical consumers.
-
Plug in the electrical system connector of the charger. The last selected operation mode is shown on the display.