Page 8
background image

At a charge condition of approximately 80 - 85 % battery voltage, charging unit begins the "Final-charging". The fourth bar is indicated on the
display - 1 -. The battery is ready for operation.

NOTE:  The "service charging" process is dependent on the degree of sulfation of the battery.

Possible malfunctions and how they are handled:

1 Displayed voltage does not match the nominal voltage: Hold the appropriate button Up (UP arrow) or Down (Down arrow), until the charging process
begins. Displayed battery voltage does not match the nominal voltage - the charging process has already begun: Press START / STOP twice. Hold the
appropriate button Up (UP arrow) or Down (Down arrow) until the charging process begins. The charger does not recognize a battery, when the battery
voltage is less than 2 V: The display remains unchanged. The selected operation mode and Ampere hours (Ah) are displayed.

End battery charging process:

-

Press START / STOP.

-

Remove the black charging clamp "-" of the charger from the negative battery terminal.

-

Remove the red charging clamp "+" of the charger from the positive battery terminal.

-

Pull out the electrical system connector of the charger.

Severely Discharged Battery, Charging

Severely Discharged Battery, Charging

CAUTION:

-

Risk of injury. Observe warning notes and safety precautions.

-

Batteries that have a colorless or light yellow visual indicator must not be tested or charged. Jump starting must not be used

-

There is a risk of explosion during testing, charging or jump starting.

-

These batteries must be replaced.

-

The polarity protection of the charger clamps is not active in the operation mode "charging severely batteries/Support mode". Connect
the charger clamps to the battery terminals correctly according to polarity

-

During the charging process, always set the operation mode corresponding with the battery operation instructions for battery charger
VAS 5900

--

The severely discharged battery is not recognized by the charger.

-

Do not touch START / STOP if the charge clamps are connected incorrectly The charger can be damaged.

It is not possible for the battery charger VAS 5900 to automatically recognize batteries with voltage under 2 Volts.

Special tools, testers and auxiliary items required