Results may be to "Replace Battery" either after testing or during charging process.

Tip:
This is normal since both MCR340V and INC-940 use a conductance test, but the INC-940 also incorporates use of a 150A load test and "sophisticated"
charging algorithm which monitors charging state of the battery.

In this case, results of INC-940 should always be used instead of MCR340V.

Charging System Test Results at: "Low Charging Voltage" Using Midtronics MCR340V Analyzer

If performing a charging system test with Midtronics MCR340V tester directly at battery:

Test results may be "Problem - Low Charging Voltage"

This result may be due to a faulty generator, however, DO NOT automatically assume the generator is faulty. The MCR340V is connected at the battery,
low charging voltage could be due to excessive voltage drop on generator battery cable, poor connections, contaminated or faulty grounds in charging
system.

To deem the generator faulty:

^

Verify charging voltage and current output, directly at generator, using the 5051 measurement tools functions.

Tip:
Test generator at the back or as close as possible to achieve accurate results.

Tip:
Failure to properly diagnose concern may lead to replacement of unnecessary parts, which could result in a denied warranty claim.

Charging System Test Result at: "Excess Ripple Detected" Using Midtronics MCR340V Analyzer

If performing a charging system test with Midtronics MCR340V tester directly at battery:

Test results may be "Problem - Excess Ripple Detected".

Tip:
Result may be due to periodic "system noise" in vehicle's electronics system or possible low battery voltage.

To ensure test results are accurate:

^

Always retest directly at battery and perform any action as directed by Midtronics tester (good, recharge or replace).

^

Perform charging system test again at battery.

Testing/Charging: INC-940 Charging Station -Automatic Mode-

When using INC-940 Battery Charging Station in "Automatic Mode", and testing or charging a deeply discharged battery:

INC-940 may continuously display a message "Are clamps connected?"

In order to test battery:

^

Manually charge battery for 30 minutes and perform test again.

Testing/Charging: INC-940 Charging Station -Manual Mode-
When using INC-940 Battery Charging Station in "Manual Mode", and testing or charging a deeply discharged battery:

INC-940 may display a message "Are clamps connected?" twice.

This is not a result of defective INC-940 test equipment, but is a safety feature of the INC-940 to ensure cables are connected to battery before power is
turned ON.

INC-940 Charging Station Always Displays "Check Connections"

INC-940 may constantly display a message to "Check Connections" after cables are connected to battery terminals.

This is most likely due to the sensing probe making contact with the clamp.