volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3587 > < Initial Inspection and Diagnostic Overview
Page 1
background image

Battery: Component Tests and General Diagnostics

AGM Battery, Checking

AGM Battery, Checking

CAUTION:

-

Risk of injury. Observe warning notes and safety precautions.

-

In order to prevent damage to the battery or vehicle, observe battery type descriptions and notes.

Perform battery checks in the following sequence:

-

Visual inspection. See: Initial Inspection and Diagnostic Overview

-

Battery, load testing using battery tester with printer VAS 5097 A  See: Battery Load Test With Battery Tester With Printer VAS 5097A

-

Depending on the result of the load test, "perform current draw test". See: Current Draw Test

Battery Load Test With Battery Tester With Printer VAS 5097A

Battery Load Test With Battery Tester With Printer VAS 5097A

CAUTION:

-

Risk of injury. Observe warning notes and safety precautions.

-

Batteries that have a colorless or light yellow visual indicator must not be tested or charged. Jump starting must not be used

-

There is a risk of explosion during testing, charging or jump starting.

-

These batteries must be replaced.

Special tools, testers and auxiliary items required

-

Battery Tester with Printer 5097 A VAS 5097 A

NOTE:  Note TPL 2012182 for Battery Tester With Printer VAS 5097 A

Perform battery load test:

NOTE:  The battery temperature must be at least 10 degrees C.

-

Turn off the ignition and all electrical consumers.

-

Check visual indicator on batteries equipped with it  See: Battery With Visual Indicator, Checking

-

Determine cold cranking amps according to specifications on battery in ampere (A) according to DIN and determine Battery Tester With Printer
VAS 5097 A adjustment range using the table Cold Cranking Output.

NOTE:  Should the battery state this value not in DIN, but rather in IEC or EN/SAE, the value should be converted with help of the table Cold
Cranking Output or the table on the device.

-

Select the cold cranking output with the cold cranking output selector switch.

-

Select the measurement range, 80 - 379 A or 380 - 499 A, with the ON/OFF function switch.

NOTE:  Batteries having a cold cranking output greater than 499A according to DIN (for example 520A, 580A or 600A), can be tested with the
setting for 499A according to DIN.

-

Clamp the red clamp "+" of the tester to the positive terminal.

-

Clamp the black clamp "-" on the tester to the negative terminal.

NOTE:
-

Make sure the test clamps make good contact

-

Note TPL 2012182 for Battery Tester With Printer VAS 5097 A

Initial Inspection and Diagnostic Overview|Page 3587 > < Initial Inspection and Diagnostic Overview