Connector assignment on high-pressure sender -G65- |
Kontakt 2 - | Signal output (square-wave signal to radiator fan control unit -J293- and to engine control unit) |
Kontakt 3 - | Positive (terminal 15) |
Note t
| Air conditioner compressor is not switched on when plug -B- is pulled out. |
t
| High-pressure sender -A- is an electronic control unit that produces a square-wave signal with a duty cycle that changes as refrigerant circuit pressure changes. |
–
| Check for short circuit between cables. |
–
| Additionally check cables for short circuit to battery positive or earth. |
If no fault is found in the cables: |
–
| Renew high-pressure sender -G65-. |
Note The high-pressure sender can be removed without extracting the refrigerant from the refrigerant circuit. |
|
|
|