Adjusting cable at temperature flap
Adjusting cable at temperature flap
  Note
Marking for cable sheath: beige
l  Heated air and fresh air blower controls with cables are installed.
l  Connecting piece → Chapter is removed.
Adjusting
–  Turn rotary temperature knob to left stop → Item.
   
–  Push wire end of cable -1- onto temperature flap lever -2-.
–  Push temperature flap lever -2- to stop -arrow A- and secure cable sheath -1- with clip -3-.
–  Turn rotary temperature knob to left and right stops.
  Note
When turning, both end stops must be reached.
  N80-0195