Test Requirements

-

The respective fuses of Heated Oxygen Sensor (HO2S) -G39- must be OK.

-

Ignition switched off.

-

Unscrew protective cover (arrows) and disconnect 6-pin harness connector (black) -1- to Heated Oxygen Sensor (HO2S) -G39- before catalytic
converter.

-

Set multimeter for resistance measurement and connect it to terminals 3 + 4 at connector for oxygen sensor. Check oxygen sensor heater for
continuity.

Specified value: 2.5...10 ohms(at room temperature)

If an open circuit is found in the oxygen sensor heater:

-

Replace Heated Oxygen Sensor (HO2S) -G39- Bank 1 before catalytic converter, item 8

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data.  See: Testing and Inspection/Scan Tool
Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data

-Generate readiness code.  See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

If oxygen sensor heater has continuity:

-

Check voltage supply and wiring

Checking Voltage Supply And Wiring

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 3468 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 3466