volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Idle Speed|Specifications|Page 2830 > < Idle Speed|Specifications|Page 2828
Page 3
background image

Specification: 0x000 (Significance)

-

Check specified idle speed in display zone 2.

Specification:

Manual transmission 760 RPM
Automatic transmission 700 RPM

-

Check actual idle speed in display zone 1.

Specification:

Manual transmission 760 to 810 RPM 1)
Automatic transmission 700 to 750 RPM 1)

1) Engine idling at normal operating temperature

NOTE:  During idling check the EVAP canister purge regulator valve and the air conditioner are switched off and the oxygen sensor control learning
procedure is initiated.

NOTE:

-

The value shown in display zone 1 is the actual engine speed.

-

The value shown in display zone 2 (specified engine speed) is a theoretical value calculated by the Motronic Engine Control Module (ECM)
-J220-.

-

When the engine is idling the Motronic Engine Control Module (ECM) -J220- tries constantly to adjust the actual engine speed so that it adapts
the specified value.

-

This means that the actual engine speed when idling should be approximately the same as the specified engine speed.

Significance of 5 digit number block

Idle Speed|Specifications|Page 2830 > < Idle Speed|Specifications|Page 2828