Electrolyte level must align with the internal electrolyte level indicator (lip) -1-. This equates to the external "maximum" marking on the battery
case.

NOTE:  On batteries with black housings, obtain accurate electrolyte level readings by illuminating inside of cells with a flashlight.

Electrolyte level too low

-

Fill with distilled water using battery filling bottle VAS 5045 (or equivalent) up to the max. marking

NOTE:  Design of filler support on filling bottle VAS 5045 prevents overfilling of battery cells and subsequent electrolyte leaks. When max. level is
reached the flow of distilled water into battery cells stops.

CAUTION!

-

Only use distilled water to top-up batteries. This prevents electrolyte impurities which cause self-discharging.

-

DO NOT overfill the battery

-

Overfilled batteries can boil over.

-

Too little electrolyte reduces the service life of the battery.

-

Use use of genuine VW battery cell caps ensures the different battery cover systems are sealed correctly. Only use genuine cell caps of the
same construction if lost or damaged. All cell caps must be equipped with an O-ring seal.

NOTE:  If it becomes necessary to top up the battery with distilled water, always perform a load test afterwards. See:  

Electrolyte level too high

Special tools, testers and auxiliary items needed

Initial Inspection and Diagnostic Overview|Page 5000 > < Initial Inspection and Diagnostic Overview|Page 4998