Restrictor and Reservoir (With Internally Regulated Compressor), Checking|Page 9073 > < Restrictor and Reservoir (With Internally Regulated Compressor), Checking|Page 9071
Page 4
background image

NOTE:

-

For the malfunction "high pressure normal, low pressure too low", note the following: If malfunctioning, evaporator may ice-up or cooling output
is not reached.

-

With this malfunction, evaporator may ice up although quantity of refrigerant in circuit is OK.

-

Check measured values of Evaporator Vent Temperature Sensor G263.

-

Check activation of A/C Compressor Regulator Valve N280