Page 3
background image

NOTE:  Design of filler support on filling bottle VAS 5045 prevents overfilling of battery cells and subsequent electrolyte leaks. When max. level
is reached the flow of distilled water into battery cells stops.

CAUTION:
-

Only use distilled water to top-up batteries. This prevents electrolyte impurities which cause self discharging.

-

DO NOT overfill the battery

-

Overfilled batteries can boil over.

-

Too little electrolyte reduces the service life of the battery.

-

Use use of genuine VW battery cell caps ensures the different battery cover systems are sealed correctly. Only use genuine cell caps of the
same construction if lost or damaged. All cell caps must be equipped with an O-ring seal.

Electrolyte level too high

Special tools, testers and auxiliary items needed

-

Commercially available hydrometer

WARNING:
-

Refer to Warnings and Safety Measures.

-

If electrolyte level is too high, electrolyte (sulfuric acid/water mixture) may leak out and damage the surrounding area, i.e.: plenum
and engine compartment.

-

Excess electrolyte MUST be extracted using a hydrometer

-

Dispose of electrolyte (sulfuric acid) properly! Waste electrolyte must only be disposed of in appropriate waste disposal sites. Refer to
local regulations pertaining to electrolyte disposal.

-

Remove cell caps from cells with excess electrolyte.