New Beetle L4-2.0L (AVH) (2005)
-
Disconnect pressure hose (arrow) from Secondary Air Injection (AIR) pump motor.
NOTE: To disengage, compress the buttons at the hose coupling.
-
Blow with light pressure into pressure hose to combination valve
Combination valve must close.
-
Blow with high pressure into pressure hose to combination valve
Combination valve must open.
If the combination valve does not open or it is constantly open:
-
Replace combination valve.
-
Erase DTC memory of Engine Control Module (ECM). Diagnostic mode 4: Reset/erase diagnostic data. See: Computers and Control
Systems/Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data
-
Generate readiness code. See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes