volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Fuel Pressure Regulator > < Fuel Injectors, Checking|Page 4956
Page 3
background image

NOTE:  In the following injection quantity test, the spray pattern must also be checked. The spray pattern must be the same for all injectors.

-

Operate remote control V.A.G1348/3 for 30 seconds.

-

Repeat check on other injectors. Use new measuring beakers.

-

After all injectors have been activated, place measuring beakers on a horizontal surface and compare injected quantity.

-

Specification: 85 to 105 ml per injector

If the measured values of one or more injectors are above or below the prescribed specifications:

-

Switch off ignition.

-

Replace faulty injector.

Observe the following when installing injectors:

-

Replace O-rings on all injectors and lightly moisten them with clean engine oil.

-

Insert injectors vertically and in the correct position into the fuel rail and secure with retaining clips.

-

Fit fuel rail with secured injectors onto intake manifold and press in evenly.

-

Read Diagnostic Trouble Code (DTC) memory of engine control module. If necessary, correct faults and erase DTC memory. See: Computers and
Control Systems/Engine Control Module/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes

Fuel Pressure Regulator > < Fuel Injectors, Checking|Page 4956