Remove ATF control plug - arrow 1 - when ATF temperature reaches 35°C.

-

Always replace the seal - arrow - for the ATF control plug.

-

ATF present in the overflow pipe - arrow2 - will drain out first.

-

If ATF continues to leak out of the ATF control pipe opening before the ATF temperature has reached 40°C, the ATF level is OK.

-

Tighten ATF control plug - arrow 1 - (with a new seal) to 27 Nm. ATF check is now completed.

Note:  Reinstall the ATF control plug at the latest before the temperature reaches 45°C (50°C for hot climates).

If no ATF leaks out before ATF temperature reaches 45°C, top up. Go to ATF level, topping up. See: Service and Repair/09G, 6 SPD. A/T/ATF
Level, Topping Up

-

End function "08 - Read measured value data block" by touching key.

-

Press on function "06 - End output".

-

Switch off ignition and disconnect diagnosis cable.