throttle valve control modules run in counter directions.

-

The percentage indicated in display zones 1 and 2 must always total approx. 100 %.

-

The voltage of angle sensor 1 moves toward 5 volts. (The more the throttle valve is opened the higher the voltage; percentage increases).

-

The voltage of angle sensor 2 drops from 5 volts toward 0 volt. (The more the throttle valve is opened the lower the voltage; percentage falls).

If the specifications are obtained:

-

Press -> button.

-

Press buttons 0 and 6 for function "End output" and confirm entry with Q button.

-

Switch ignition off.

If the displays do not indicate as described:

-

Press -> button.

-

Press buttons 0 and 6 for function "End output" and confirm entry with Q button.

-

Switch ignition off.

-

Remove inner plenum chamber cover, left:

-

Connect test box V.A.G 1598/31 to control module wiring harness. Engine control module is not connected by this action.

-

Measure resistance of throttle valve drive between test box sockets 117 + 118
Specification: 1.0. to 5.0 Ohms

If the specification is not obtained:

-

Replace throttle valve control module (J338)

-

Check DTC memory, if necessary, repair any malfunctions and then erase DTC memory. See: Powertrain Management/Computers and Control
Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Reading Diagnostic Trouble Codes   

-

Adapt engine control module to throttle valve control module. 

-

Read readiness code. If DTC memory has been erased or engine control module was disconnected from permanent positive, readiness code must
be generated again. See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and
Readiness Codes See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and
Readiness Codes 

If the specification is obtained:

-

Check voltage supply of throttle valve control module and wiring to control module.

-

Check accelerator pedal sensor (E-Gas).

If the voltage supply and wiring is OK:

-

Replace Engine Control Module (ECM).