Connect multimeter to terminal 4 of connector and engine Ground (GND) for voltage measurement.

-

Switch ignition on. Specified value: at least 4.5 V

-

Switch ignition off.

If there is no voltage:

-

Check signal and Ground (GND) wire of Mass Air Flow (MAF) sensor.

Checking signal and Ground wires of Mass Air Flow (MAF) Sensor

-

Connect test box to control module wiring harness, connect test box for wiring test. Engine Control Module (ECM) is not connected.  See:
Powertrain Management/Computers and Control Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool
Connecting/With Generic Scan Tool/Test Box, Connecting For Wiring Test

Vehicles with engine code AEG

-

Check wires between test box and 5-pin connector for open circuit according to wiring diagram. Terminal 3 + socket 12, Terminal 4 + socket 11,
Terminal 5 + socket 13: Wire resistance: max. 1.5 Ohms

Vehicles with engine code AVH, AZG, BDC

-

Check wires between test box and 5-pin connector for open circuit according to wiring diagram. Terminal 3 + test box socket 27, Terminal 4 + test
box socket 53, Terminal 5 + test box socket 29: Wire resistance: max. 1.5 Ohms

Continuation for all vehicles

-

Also check wires for short circuit to each other, to vehicle Ground (GND) and to B+. Specified value: Infinite Ohms