Instrument Panel Control Module: All Technical Service Bulletins
Antitheft - No Start Condition Below 40 Degrees F.

90 08 03

February 6, 2008

2011326, Supercedes T.B. Group 90 number 05-08 dated November 18, 2005 due to Service Action M4 expiring.

Affected Vehicles

Condition

Immobilizer Activated If Ambient Temperature Is Below 4°C (40°F)

An intermittent No Start condition may exist in ambient temperatures below 4°C (40°F):

^

The vehicle cranks but does not start after sitting for long periods or over night

^

The electronic immobilizer light is flashing

^

The vehicle cannot be started with any of the keys

When the concern can be reproduced the following fault codes may be present:

^

P1570 in 01 - Engine Electronics

^

01176 in 25 - Immobilizer

Technical Background

N/A

Production Solution

N/A

Service

^

Verify if instrument cluster has already been updated:

^

Tilt steering wheel down in order to see white label on bottom of instrument cluster.

If a letter "C" is printed on the label, part has already been updated. 

If a letter "C" is not on label, a new instrument cluster has to be ordered for the vehicle based on the Vehicle Identification Number (VIN).