Using the number pad on the display - arrow - press buttons 4 and 5.

Adaptation channel 45 adapts the instrument panel insert to the quality of oil.

-

Confirm entry with "Q" button on display number block. 

Indicated on display:

-

Drag the cursor - arrow - on the display to the left, until the adaptation value - 1 - is indicated above the scroll bar 1.

‹› The adaptation value shows the current status of the engine oil quality: 

4

LongLife Service diesel engines: engine oil conforming to VW standard 506 00 (TDI) or VW standard 506 01 (PD TDI)

2

LongLife Service for gasoline engines: engine oil conforming to VW standard 503 00

1

Time- or distance-dependent service: no engine oil according to VW-Norm 503 00 (gasoline engines), 506 00 (TDI) or 506 01 (pump injector
TDI)

‹› If the instrument panel insert is to be coded to "flexible" (LongLife service), the adaptation value 4 must be selected for diesel engines and/or the

adaptation value 2 must be selected for gasoline engines.

By selecting the adaptation value 1, the instrument panel insert is coded "non-flexible", i.e. "time or distance dependent ".

-

Press the "Save" button - 2 - on display. 